[. . . ] REFER SERVICING TO QUALIFIED SERVICE PERSONNEL. WARNING: To reduce the risk of fire or electric shock, do not expose this appliance to rain or other moisture. CAUTION: Changes or modifications not expressly approved by the manufacturer may void the user's authority to operate this equipment. For the customers in Canada This class B digital apparatus complies with Canadian ICES-003. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generated, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. [. . . ] (Please refer to page 24, "Setting the Mode at the End of the Tape". ) 5 Press the MENU EXIT button to save the setting. ø The REPEAT indicator will light. 6 Press the REC/PLAY SPEED l (or j) button to set the recording speed mode. 7 Press the REC button. ø Recording will start. When the tape end is reached, the VCR will rewind it to the beginning, and recording will resume. ø When the end of the tape is reached, a buzzer will be heard (if in the (BUZZER SET) menu, TAPE END is set to "Y") and "OFF" will be displayed until the rewinding operation starts. 26 English ALARM RECORDING By connecting the ALARM IN terminal to a door switch, an interphone, etc. , a recording can be done only when necessary. 4 Press the DATA l (or j) button to select the desired recording speed, then press the SHIFT ] button. Recording at the speed already set Alarm Recording Setting Alarm recording is performed when there is an input (trigger) at the ALARM IN terminal, "A" is displayed on the digital display. oe Follow the Before starting steps, under "NORMAL RECORDING". oe The alarm triggers are received while in recording and stop modes. 5 Press the DATA l (or j) button to select the desired alarm recording duration (20S, 40S, 1M, 2M, 3M, 4M, 5M or CC). Recording as long as the alarm signal is being input (minimum 5 seconds) 1 Press the MENU button to display the (MAIN MENU 1) menu. 2 Press the SHIFT ] button to select the "6. REW 6 Press the MENU EXIT button to save the settings. NOTES: oe During alarm recording all buttons are disabled. oe If "OFF" is displayed on the digital display, alarm recording is not possible in order to prevent the recorded tape to be recorded over. oe If an alarm trigger is received while alarm recording is in progress, recording duration for the second alarm will be calculated from that point. The alarm counter will register the alarm, but it will not be found during an alarm scan and alarm search. (Please refer to the illustration below. ) Playback Alarm number 2 Alarm trigger input point Rewind direction Fast-forward direction 1 1 2 3 While the desired recording is being played back, press the PLAY button. ø Playback will start, alarm scan mode is cancelled. Actual position NOTE: oe If during a scan the end of the tape is reached, the tape will rewind and stop. If the beginning of the tape is reached, it will stop. 3 Press the PLAY button. ø Playback will start. NOTE: oe If during a search the end of the tape is reached, the tape will rewind and stop. If the beginning of the tape is reached, it will stop. English 29 ALARM RECORDING Pre Alarm Recording Setting When there is an alarm trigger, the pictures accumulated into the memory previous to the alarm trigger can be recorded using the set recording speed mode (duration). oe This will be activated by an alarm trigger if the "ALARM RECORD MODE" is set to "Y1", "Y3" or "Y4" and the VCR is in stop mode. Post Alarm Recording Setting After the alarm recording, you can set recording of the picture to continue at a set recording speed mode, for only a set duration. 1 Follow the steps 1 and 2 under "Alarm recording Setting" on page 27. 1 Follow steps 1 and 2 under "Alarm Recording Setting" on page 27. REW 2 Press the SHIFT ] button, until the "POST ALARM RECORD" setting is flashing. 3 Press the DATA l (or j) button to select the recording speed mode, then press the SHIFT ] button. OFF F12 F24 F48 F72 F96 F120 F168 2 Press the SHIFT ] button, until the "PRE ALARM RECORD" setting is flashing. OFF. Postalarm recording is not performed 3 Press the DATA l (or j) button to select the recording speed mode. The recording duration will vary according to the recording speed mode. 4 Press the DATA l (or j) button to select the postalarm duration. Recording only for the displayed duration OFF F12 F24 F48 F72 F96 F120 F168 5 Press the MENU EXIT button to save the settings. OFF . Prealarm recording is not performed Recording speed mode F12 F24 F48 F72 F96 F120 F168 Recording duration (seconds) 18 36 72 108 144 180 252 4 Press the MENU EXIT button to save the settings. 30 English PROGRAM TIMER RECORDING There are two program timer recording methods, daily recording or recording on certain days of the week. 8 Press the DATA l (or j) button to set the recording ø The "SPD" (recording speed) position will start flashing. stop minutes (ex: 00), then press the SHIFT * button. Example 1: To record on every Saturday from 9:00 AM to 5:00 PM (17:00), in H24-hour mode (recording speed). oe Follow the Before starting steps, under "NORMAL RECORDING". NOTE: oe If the set stop time is earlier than or the same time as the set start time, the VCR will consider the stop time to be the following day, and "T" will be displayed next to the recording stop time. 1 Press the MENU button to display the (MAIN MENU 1) menu. 2 Press the SHIFT ] button to select the "7. [. . . ] After the battery has been replaced, press the ALL RESET button, then enter all the time, date, etc. settings as required. English 51 MAINTENANCE Maintaining and Checking The Mechanism To maintain the VCR functions and features working properly, and to avoid damages or dirt on the tape, it is recommended to follow the maintenance points and periodicity indicated below. For detailed information, please contact your dealer. Maintenance Table PARTS Tape Path System ASSY, BRAKE BAND ASSY, LEVER BT (tape guide) FULL ERASE HEAD ASSY, ROLLER CLEANER ASSY, GUIDE ROLLER ASSY, MOUNTING INCLNE S ASSY, MOUNTING INCLNE T ACE HEAD ASSY, LEVER PINCH ROLLER MOUNTING, LIFT PINCH CAM, LIFT PINCH GEAR, CAM PINCH ASSY, EARTH CYL COMPL, CYLINDER ASSY, CYLINDER UPPER Reel Drive System ASSY, REEL SUPPLY ASSY, REEL TAKEUP GEAR, REEL S GEAR, REEL T PULLEY, REEL SPECIAL, WASHER 2. 4 X 6 X 0. 25 COMPL, MOUNTING CLUTCH BELT, REEL MOTOR, CAPSTAN ASSY, GEAR FRICTION Brake ASSY, BRAKE S ASSY, BRAKE T ASSY, BRAKE CAPSTAN ASSY, BRAKE SOFT T Loading Drive ASSY, LOADING MOTOR System DAMPER COMPL, GEAR WORM CAM, MAIN SPECIAL WASHER 3. 6 X 0. 5 GEAR, WHEEL 1 GEAR, WHEEL 2 MODE SWITCH SLIDE, CRECENT GEAR, LOAD S GEAR, RACK FRONT GEAR, RACK START GEAR, PINON Performance BACK TENSION TORQUE Check FWD, REW TORQUE PLAY TORQUE REV TORQUE 2000H E F F E F F F F F 4000H k F F k F F F F k F : Cleaning 6000H E F F E F F F F F E : Confirmation 8000H k F k k F k k k k k k k k F(k) F(k) Fv Fv v v v E k k k vk E E E k k k k k k k k k k k k k k E E E E v : Lubrication NOTES k : Change F F(k) Fv Fv v v v v E F v E E E k F(k) F(k) Fv Fv v v v E k k E(k) vk E E E E E E E E E E E E E E E E E E F F(k) Fv Fv v v v v E(k) v E E E E E E E E E E E PB BACK TENSION TORQUE 25~50gcm FWD, REW TORQUE 600gcm PLAY 55 ~ 110gcm REV 100 ~ 210gcm NOTE: 1. For places with symbols such as E (k) and F (k), carry out checking and cleaning, and replace if necessary. [. . . ]